Made with FlowPaper - Flipbook Maker
Eaton Product Handbook2 CHOOSING THE RIGHT UPS HOW TO BUY UPS SELECTION | HOW TO BUY When it comes to backup power there are some basic questions to ask your customer. Getting the right information is the first step to providing them with a tailored power solution. The only remaining step is getting in touch with UPS Power Solutions industry leading UPS experts! Option #3 Call our knowledgeable sales team on 0800 COMPUT (0800 266 788) Option #2 Email Us sales@cdl.co.nz Option #1 Visit Our Website www.cdlnz.com 1. Application and Load a. What is the UPS going to support e.g. Communication equipment, Point of Sale, or CCTV, if LED lighting ask for inrush current specification b. What size is the load that you need to protect in kVA or Watts? 2. UPS Specifics a. How long do you need battery backup to last in minutes? b. What form factor is required? Rack or Tower and note any physical space restraints c. What type and number of output receptacles are required. ANZ 3 pin or IEC 3. Accessories a. Is a maintenance bypass switch required for uninterrupted servicing and replacement? b. Do you want to remotely monitor the UPS? Via the network (SNMP) or via the building management system Dry contact alarms3 UPS Selector Guide4 The Nine Power Problems6 Selecting the Right UPS7 Eaton 3S UPS8 Eaton 5E UPS9 Eaton 5S UPS10 Eaton 5SC (Rack) UPS11 Eaton 5SX UPS12 Eaton 5P UPS14 Eaton 5P Lithium-ion UPS15 Eaton 5PX Gen 2 UPS16 Eaton 9SX Tower UPS18 Eaton 9PX UPS (1-3KVA)20 Eaton 9PX UPS (5-11KVA)22 Eaton 9PX Lithium-ion UPS24 Eaton 9E UPS26 Options to Manage & Monitor Your UPS27 PDU and Maintenance Bypass28 UPS Replacement Battery Selector29 Notes30 CONTENTS PAGE CONTENTS PAGE4 3 SERIES STANDBY UPS - BACK UP POWER 5 SERIES LINE-INTERACTIVE UPS - KEEPING IT SMOOTH UPS SELECTOR GUIDE 5EPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Tower5E650IUSB-AU650/360 Aus 10 Fixed Input Lead 2 x USB2 Years 5E850IUSB-AU850/4802 x 5E1100IUSB-AU1100/6603 x 5E1500IUSB-AU1500/9003 x 5E2000IUSB-AU2000/12003 x 3SPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Plugboard3S600AU600/360 Aus 10 Amp x 4 surge x 4 battery USB2 Years 3S850AU850/510 5SPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Tower5S550AU550/330 Aus 10 Amp 3 x battery + surge 3 x surge only USB2 Years 5S700AU700/420 5S850AU850/510 5S1200AU1200/750 5S1600AU1600/1000 UPS SELECTOR GUIDE 5PPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Tower5P650AU (T)650/420 Aus 10 Fixed Input Lead 2 x , 3 x USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS 3 Years 5P850AU (T)850/6002 x , 3 x 5P1150AU (T)1150/7702 x , 3 x 5P1550AU (T)1550/11002 x , 3 x 5SCPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack 5SC1500IR-AU1500/1050Aus 10 Amp 8 x USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS PDUBHV101U2 Years 5SXPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack / Tower 5SX1250AU1250/1125 IEC C14 8 x 5SXEBM48R2U (can have maximum of 2) USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS PDUBHV101U 2 Years5SX1750AU1750/15758 x 5SXEBM48R2U (max 2) 5SX3000AU3000/2700 IEC C20 6 x , 1 x 5SXEBM72R2U (max 2)MBP3KI 5SXRACKKIT2UIf Rackmounting add 5PPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack5P650iR (R)650/420 IEC C14 4 x USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS PDUBHV101U3 Years 5P850iR (R)850/600 4 x 5P1150iR (R)1150/770 6 x 5P1550iR (R)1550/1100 6 x 5P Lithium IonPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack5P1550GR-L1550/1100 IEC C13 6 x USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS PDUBHV101U5 Years5 5PX Gen 2Part NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack / Tower5PX1500IRT2UAUG21500/1350 IEC C14 8 x 5PXEBM48RT (max 4) USB/RS232 and 1 communication slot for either Net- work-M2 or RELAY-MS PDUBHV101U 3 years 5PX2000IRT2UAUG22000/1800 5PXEBM72RT3U (max 4 ) PDUBHV101U 5PX2200IRT2UAUG22200/1980 8 x , 1 x MBP3KI 5PX3000IRT2UAUG2 3000/2700 IEC C20 MBP3KI 5PX3000IRT3UAUG2MBP3KI 9 SERIES ONLINE UPS - TOTAL PROTECTION APPLICATIONS Switch board & controls Desktops Servers Motors Point of sale Emergency lighting Home 9SXPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Tower 9SX700I-AU700/630 IEC C14 4 x NA USB/RS232 and 1 communication slot for either Network-M2 or RELAY-MS PDUBHV101U 2 years 9SX1000I-AU1000/9004 x 9SXEBM36T (max 4)PDUBHV101U 9SX1500I-AU1500/13504 x 9SXEBM48T (max 4)PDUBHV101U 9SX2000I-AU2000/18005 x , 1 x 9SXEBM96T (max 4)PDUBHV101U 9SX3000I-AU3000/2700 IEC C19 5 x , 1 x 9SXEBM96T (max 4)MBP3KI 9SX6KI-AU3000/2700 Hard Wired Ph = N = E Terminal block 9SXEBM240T (max 4)6000MBS1-BFP Storage 9EPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Tower 9E1000IAU1000/800 Aus 10 Amp 4 x NA USB/RS232 and 1 communication slot for either Network-M2 or RELAY-MS PDUBHV101U 1 year 9E2000IAU2000/16006 x 9EEBM72 PDUBHV101U 9E3000IAU3000/24006 x MBP3KI 9E6KI6000/4800 Hard Wired Terminal block9EEBM1806000MBS1-MT Communications 9PX 5-11KVAPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack/Tower 9PX5Ki5000 Hard Wired HW, 2 x , 8 x 9PXEBM180 (max 4) USB/RS232 and 1 communication slot for either Network-M2 or RELAY-MS DB9 (4) Dry Contacts/ DB15 Parallel MBP6KI 3 Years 9PX6Ki6000/5400HW, 2 x , 8 x 9PXEBM180 (max 4)MBP6KI 9PX8KiPM + 9PXEBM240 8000/7200HW, 4 x 9PXEBM240 (max 4 or 12 with supercharger SC240RT module) MBP11Ki 9PX11KiPM + 9PXEBM240 11000/10000HW, 4 x MBP11Ki 9PX 1-3KVAPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack / Tower 9PX1000IRT2U1000 IEC C14 8 x 9PXEBM48RT2U (max 4) USB/RS232 and 1 communication slot for either Network-M2 or RELAY-MS Output Relay PDUBHV101U 3 Years 9PX1500IRT2U15008 x PDUBHV101U 9PX2000iRTAU2000 IEC C20 6 x , 2 x 9PXEBM48RT2U (max 4) PDUBHV101U 9PX2200IRT2U22008 x 2 x MBP3KI 9PX2200IRT3U22008 x , 2 x 9PXEBM72RT3U (Max 4)MBP3KI 9PX3000IRT2U30008 x , 2 x 9PXEBM72RT2U (Max 4)MBP3KI 9PX3000IRT3U30008 x , 2 x 9PXEBM72RT3U (Max 4)MBP3KI CCTV INPUT / OUTLET Aus 10 Amp IEC C13/14 IEC C19/20 9PX Lithium IonPart NumberVA/WattsInputOutletEBMCommsBypass SwitchWarrantyApplications Rack 9PX1500IRTANZ-L1500/1500 IEC C14 8 x 9PXEBM48RT1U-L USB/RS232, mini-ter- minal block and 1 communication slot for either Network-M2 or RELAY-MS. PDUBHV101U 5 Years 9PX2000IRTAU-L2000/18008 x , 2 x 9PXEBM72RT1U-L 9PX3000IRTANZ-L3000/2400 IEC C20 8 x , 2 x MBP3KITHE NINE POWER PROBLEMS POWER PROBLEM DEFINITION Power Power Power Under- Over- 2. Power sag Post-lunch sleepiness or short-term low voltage. 3. Power surge (spike) Rush of energy following a double shot of espresso or short-term high voltage more than 110 percent of normal. 4. Under-voltage (brownout) When your amp’s too wimpy to handle the bass line or reduced line voltage for an extended period of a few minutes to a few days. Often happens during the summer months when everyone is cranking up their air conditioners. 5. Over-voltage Inhumane cheerfulness exuded by aerobics instructors or increased line voltage for an extended period of a few minutes to a few days. 1. Power failure When a superhero loses his ability to fly or a total loss of utility power. 6. Electrical line noise Excuse you use to get off the phone quickly or a high power frequency power wave caused by radio frequency interference (RFI) or electromagnetic interference (EMI). 7. Frequency variation Fluctuation in how often you do laundry from week to week or a loss of stability in the power supply’s normal frequency of 50 or 60 Hz. 8. Switching transient Breaking up with your significant other only to get back together every six months or instantaneous under-voltage in the range of nanoseconds. 9. Harmonic distortion “Music” blaring from your nephew’s headphones or the distortion of the normal power wave, generally transmitted by unequal loads. Line Frequency Switching Harmonic In an ideal world, your wall socket would provide an infinite stream of perfect power, at constant voltage and cycling exactly the same number of times per second. Don’t count on it. The nine power problems listed below are potentially harmful to both your data and your equipment. THE NINE POWER PROBLEMS7 Eaton’s power management solutions are based on protecting the connected load from the nine most common power problems present in any environment. There are three different UPS topologies that provide varying degrees of protection. Selecting the best fit depends on several factors, including the level of reliability and availability desired, the type of equipment being protected and the application/environment. Eaton’s products are grouped into three levels of power protection: Series 3, Series 5 and Series 9. This unique approach makes your product selection much simpler. Within both Series 5 and 9 Eaton has created 3 classes of products to provide “Good (E), Better (S) and Best (P)” levels of features and performance. This enables the best product fit for any application and budget. UPS TOPOLOGIES SELECTING THE RIGHT UPS Eaton’s series 9 UPSs protect against all nine power problems: power failures, power sags, power surges, under-voltage, over-voltage, line noise, frequency variation, switching transients and harmonic distortion. Online UPSs provide the highest level of protection by isolating equipment from raw utility power— converting power from AC to DC and back to AC. Unlike other topologies, double conversion provides zero transfer time to battery for sensitive equipment. This topology is best applied to mission-critical equipment and locations where power generally is poor. SERIES 9 | ONLINE DOUBLE CONVERSION UPS: TOTAL PROTECTION Switching Transient Line Noise Frequency Variation Harmonic Distortion Over- voltage Under- voltage Power Failure Power Surge Power Sag Eaton’s series 5 UPS are most effective against five power problems (power failures, power sags, power surges, under-voltage and over-voltage) and offer protection against other power problems. Line-interactive UPSs regulate voltage either by boosting or decreasing utility power before allowing it to pass to the protected equipment or by resorting to battery power. Line-interactive models are ideal for protection against power anomalies where the utility power is relatively clean. MDF and IDF communication closets, non-centralised server and network rooms, and general IT enclosures are ideally suited for this topology. Over- voltage Under- voltage Power Failure Power Surge Power Sag SERIES 5 | LINE INTERACTIVE UPS: KEEPING IT SMOOTH The Eaton’s series 3 UPS primarily protects against three of the nine power problems including power failures, power sags and power surges. Standby UPSs allow equipment to run off utility power until the UPS detects a problem, at which point it switches to battery power to protect against sags, surges or outages. This topology is best suited for applications requiring simple backup such as small office/home office and point-of-sale equipment. Power Failure Power Surge Power Sag SERIES 3 | STANDBY UPS: BACKUP POWER8 3 SERIES STANDBY UPS | Back up power EATON 3S UPS EATON 3S TECHNICAL SPECIFICATIONS The Eaton 3S UPS helps to protect your computer equipment in case of everyday events such as lightning strikes, storms, over-demand on the utility grid, accidents, and natural disasters knocking out power without warning. It also protects telephone, broadband and Ethernet lines from ‘back door’ power surges. The compact units fit easily on or under your desk or can be wall mounted, providing power and surge protection for desktop computers, wireless networks, gaming consoles, and other critical equipment in your home or business. The 850VA models have USB powered outlets for charging devices such as cellphones and tablets. Rating (VA/W)600VA/360W850VA/510W Connection Output connection4 outlets with battery backup and surge protection + 4 outlets with surge protection only Electrical characteristics Nominal input voltage220 - 240 V Input voltage rangeUp to 168 - 295 V (adjustable) Output voltage240V (adjustable to 220V/230V/240V) Input frequency range50 / 60 Hz (46 - 65 Hz working range) Input protection10A resettable circuit breaker Battery Battery typeCompact, sealed lead acid battery (replaceable) Battery testYes Cold start (no mains power)Yes Deep-discharge protectionYes Battery replacement indicatorLED Desktop PC*16 Min20 Min Gaming PC / Workstation*6 Min9 Min Features CommunicationUSB port (HID-compliant) for automatic integration with most common operating systems (Windows & Mac OS) USB charge-2 USB ports (2A max) Phone/xDSL line Protection-Yes Operating conditions, Standards and Approvals Operating temperature0 to 40o C Operating elevation0 to 3000m CompliancesIEC 62040-1; IEC 62040-2 C2; IEC 62040-3; IEC 62040-4; IEC 61643-11 ConformityCE/ RCM Dimensions W x H x D / Weight UPS Dimensions (mm) / (kg)325x86x140 / 3.2335x86x170 / 3.2 Part Numbers35600AU35850AU * Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. IDEAL FOR PROTECTING Desktop Home Point of Sale POWER RATING 650 - 850 VA FORM FACTOR Plugboard COMMUNICATIONS USB WARRANTY 2 Years 4 AU outlets with surge protection 4 AU outlets with battery backup & surge protection On / Off button LED interface USB Communication Replaceable battery Reset button (circuit breaker) Wall-mounting system USB Charge (850 only) Phone/xDSL line protection (850 only) EATON 3S 850 AU9 5 SERIES LINE-INTERACTIVE UPS | Keeping it smooth EATON 5E UPS TECHNICAL SPECIFICATIONS Technical Specifications650850110015002000 Rating (VA/W)650VA/360W850VA/480W1100VA/660W1500VA/900W2000VA/1200W Electrical Characteristics TechnologyLine-Interactive (AVR with Booster + Fader) Input voltage range170-280V Output voltage230V Frequency50-60 Hz autoselect Connections Number of AUS outlets23 Batteries Typical backup times for 1 PC*16 min20 min45 min50 min50 min Typical backup times for 2 PC*6 min8 min20 min26 min26 min Typical backup times for 3 PC*--7 min10 min10 min Typical backup times for 4 PC*----5 min Battery managementPermanent battery charge, cold start Communication User InterfaceLED CommunicationPort HID-compliant USB port for automatic integration with most common operating systems (Windows & Mac OS) Standards Safety & EMCIEC/EN 62040-1, IEC/EN 62040 -2, C-Tick Dimensions & Weight Dimensions H x W x D148 x 100 x 288 mm180 x 133 x 330 mm Weight4.6kg5.1kg9.3kg10.5kg10.5kg Customer Service & Support Warranty2 Years Part Numbers650850110015002000 5E5E650iUSB-AU5E850iUSB-AU5E1100iUSB-AU5E1500iUSB-AU5E2000iUSB-AU EATON 5E UPS LED user interface - On/Off button USB port Battery replacement panel The Eaton 5E line interactive uninterruptible power system (UPS) provides affordable power protection for your personal computer and peripherals. It’s compact size is ideal for limited office and home working spaces. Even in disturbed electrical environments, voltage fluctuations are automatically corrected using an AVR device (booster/fader), without needing the batteries. 5E’s compact form factor allows it to be easily integrated into environments with space constraints. The 5E features an HID-compliant USB port, for automatic integration with common operating systems (Windows/ Mac OS/Linux). The 650 & 850VA models have no fan so are perfect for deployment at an operators workstation, where fan noise can be an issue. IDEAL FOR PROTECTING Desktop Home Point of Sale CCTV POWER RATING 650 - 2000 VA FORM FACTOR Tower COMMUNICATIONS USB WARRANTY 2 Years Fixed input cord ANZ outlets FanNext >